home > product details uaf500s model input voltage [v] output wattage [w] dc output [v/a] uaf500s-3 ac 85 - 264 300 3v 100a uaf500s-5 ac 85 - 264 500 5v 100a uaf500s-12 ac 85 - 264 516 12v 43a uaf500s-24 ac 85 - 264 528 24v 22a UAF500S-48 ac 85 - 264 528 48v 11a features harmonic attenuator, pfc (com plies with iec61000-3-2) universal input (ac85-264v) built-in inrush current protection power factor 0.99 remote sensing parallel and master-slave operation thin profile built-in over current protection built-in over voltage protection rohs compliant safety agency approvals ul1950, csa c22.2 no.234, en60950, vde0160 emi compliance fcc-b cispr22-b en55022-b vcci-b 3 year warranty(refer to instruction manual)
model uaf500s-3 uaf500s-5 uaf500s-12 uaf500s-24 UAF500S-48 max output wattage[w] 300 500 516 528 528 dc output 3v 100a 5v 100a 12v 43a 24v 22a 48v 11a specifications model uaf500s-3 uaf500s-5 uaf500s-12 uaf500s-24 UAF500S-48 input voltage[v] ac85 - 264 1 f ( rated input:ac100 / 200 ) current[a] acin 100v 4.5typ ( io=100% ) 6.8typ ( io=100% ) acin 200v 2.3typ ( io=100% ) 3.4typ ( io=100% ) frequency[hz] 50/60 ( 47-63 ) efficiency[%] 67typ 74typ 77typ 77typ 80typ power factor 0.99typ ( at rated input/output ) inrush current[a] acin 100v 15typ ( io=100% ) acin 200v 30typ ( io=100% ) leakage current[ma] 0.75max output voltage[v] 3 5 122448 current[a] 100 100 43 22 11 line regulation[mv] 40max 40max 80max 100max 192max load regulation[mv] 80max 80max 120max 160max 300max ripple[mvp-p] 0to+50 c * 1 100max 100max 120max 120max 150max -10 - 0 c * 1 120max 120max 150max 150max 200max ripple noise[mvp-p] 0to+50 c * 1 120max 120max 150max 150max 350max -10 - 0 c * 1 180max 180max 200max 200max 400max temperature regulation[mv] 40max 50max 160max 200max 480max drift[mv] * 2 12max 20max 48max 96max 192max start-up time[ms] 800max ( acin 85v , io=100% ) hold-up time[ms] 30typ 20typ output voltage adjustment range[v] 2.85 - 3.6 +10% , -5% protection circuit and others overcurrent protection works over 105% of rating and recovers automatically overvoltage protection 4.00 - 5.25v works at 115 - 140% of rating operating indication led ( green ) remote sensing provided isolation input-output ac3 , 000v 1minute , cutoff current = 25ma , dc500v 50m w min ( at room temperature ) input-fg ac2 , 000v 1minute , cutoff current = 25ma , dc500v 50m w min ( at room temperature ) output-fg ac500v 1minute , cutoff current = 100ma , dc500v 50m w min ( at room temperature ) environment operating temp. , humid.and altitude -10 to +60 c , 10 - 90%rh ( non condensing )( refer to derating curve ), 3 , 000m ( 10 , 000feet ) max storage temp. , humid.and altitude -20 to +75 c , 10 - 90%rh ( non condensing ), 9 , 000m ( 30 , 000feet ) max vibration 10 - 55hz , 19.6m/s 2 ( 2g ), 3minutes period , 60minutes each along x , y and z axis impact 196.1m/s 2 ( 20g ), 11ms , once each x , y and z axis safety and noise regulations agency approvals ul60950-1 , csa c22.2 no.234 , en60950-1 , en50178 complies with iec60950-1 conducted noise complies with fcc-b , cispr22-b , en55022-b , vcci-b harmonic attenuator complies with iec61000-3-2 others case size/weight 140 x 45 x 278 ( 308 ) mm ( without terminal block )( w x h x d ) /2.4kg max , 2.6kg max ( with fan unit ) cooling method forced air * 1 measured by 20mhz oscilloscope or ripple-noise meter(equivalent to keisoku-giken:rm101). * 2 drift is the change in dc output for an eight hour period after a half-hour warm-up at 25 c , with the input voltage held constant at the rated input/output. uaf500s unit type ua f 500 s -5 - o ordering information 1 series name 2 universal input 3 output wattage 4 single output 5 output voltage 6 optional c :with coating f :with fan unit g :low leakage current r :with remote on/off r 123456 uaf a-162 the forced air with the fan is necessary. rohs : please consult us for details
? harmoinc current (uaf500s-5) ? overcurrent characteristics (uaf500s-5) ? rise time & fall time (uaf500s-5) ? harmonic current (uaf500s-5) uaf a-163 uaf500s external view ?dimensions with ( )is for reference. ?weight : 2.4kg or less (2.6kg or less when fan unit is attached) ?tolerance : t 1 ?dimensions in mm. ?cover : aluminum ?maximum 50a per pin of tb2 . ?mounting torque: 1.2n . m(12.8kgf . cm)max i/o connector cn1 s10b-zr zhr-10 chain: szh-002t-p0.5 loose: bzh-002t-p0.5 (mfr.j.s.t.) mating connector terminal "a" means connection is not possible. performance data
|